Enamel glass thermometer sleeve type: Mainly divided into type A and type B. Type A is a glass lined thermometer sleeve without a temperature measuring head device, while Type B is a glass lined thermometer sleeve with a temperature measuring head device.
Size: The nominal diameter of Type A is 32~80mm, and the nominal diameter of Type B is 50~80mm. In addition, there are also specifications such as DN501250, DN651700, as well as models with different capacities such as 50L to 20000L to choose from.
Other: Glass lined thermometer sleeves can also be customized according to actual needs to meet specific process and equipment requirements.
Glass lined thermometer sleeves are widely used in equipment such as glass lined reaction vessels, with advantages such as simple structure, easy installation and operation, and safety and reliability. When choosing a glass lined thermometer sleeve, it should be selected according to the specific usage environment and process requirements to ensure that it can meet production needs and have good performance.

To prevent glass lined thermometer tube failures, attention should be paid to the following points:
Temperature management: Avoid sudden cooling and heating, control the temperature change rate at 3-5 ℃/minute to prevent thermal stress damage.
Mechanical protection: Strictly prevent collisions with hard objects, avoid using metal tools to stir inside the equipment, and prevent scratching the enamel surface.
Corrosion protection: Avoid contact with corrosive liquids, clean in a timely manner, and keep equipment clean, especially mechanical seal parts.